Designed as a companion part for use with TriMark's single rotor latches and cage nuts that requires a .500" (12.7mm) diameter striker bolt and compliance to FMVSS 206 (ECE R11). It is available in a variety of lengths with several drive details and mounting thread choices.

Installation

  • Torque to 35 ft-lbs (46.7 N-m) minimum depending upon surface conditions 

Material

  • Typical materials include AISI 4140 and AISI
  • C10B21 steel (or equivalent), heat treated to TriMark ES-141

Individual part dimensions are for reference only. Refer to individual part drawings for complete dimensions, specifications, and installation procedures. Engineering assistance and application drawings are available.

Caution: TriMark striker bolts are designed and tested to meet or exceed FMVSS 206 (ECE R11) safety requirements only when used with TriMark's corresponding FMVSS 206 (ECE R11) compliant latches. Note that some of the longer striker bolts have diminished load values in certain latch families. Please check with TriMark Engineering before finalizing your striker selection requiring FMVSS 206 (ECE R11) compliance.

Finish

  • Zinc plated with clear chromate

Latch & Striker Installation

  • Install striker bolt in door frame
  • Close door carefully and check for interference between head of striker bolt and latch components
  • Add or remove shims under striker bolt washer as required (outside diameter of shim should be larger than outside diameter of striker bolt washer)
  • Adjust striker bolt vertically so door is not guided upward or downward while being closed
  • CHECK TO DETERMINE THAT BOTH SECONDARY AND PRIMARY LATCHING POSITIONS ARE USABLE
  • Door should be latched but not "closed" in secondary position and latched to anticipated "closed" position with respect to adjacent surfaces in primary position
  • If both primary and secondary positions are not evident, readjust striker bolt
  • After installation, check door alignment and door seal pressures

Typical Uses

Typical application use illustrations are organized by Industry/System and are intended to give the user some ideas for specifying a complete system using TriMark products.

Not all Industry/System applications have typical use illustrations. If a typical use illustration is not available for your specific application, please submit a technical product information request and a technical representative can assist you in selecting a product(s) solution for your specific application.

070-0100 .500" (12.7mm) Diameter Striker Bolt

Please specify search criteria:


©2024 TriMark Corporation. All rights reserved.     Privacy  •  Legal Info  •  Terms and Conditions of Sale